Product Details:| Minimum Order Quantity | 1 Piece |
| Brand | M Power Electricals |
| Grade | Semi-Automatic, Automatic, Manual |
| Control | MCU Based Conrol Unit |
| Features | 1)foolproof circuit design 2)Light weight and Easy to handle |
| Indications | Zero interlock(yellow),HV on (Green),Overload trip (Red) |
| Output Current | 50mA AC / 25mA DC (As Per Customer Requirement) |
| Output Voltage | (0-80kV ) AC / DC |
| Phase | Single Phase and Three Phase |
| Finishing | water proof sticker and hard Plastic |
| Power Frequency | 50 Hz +/- 5% |
| Input Voltage | 230V AC +/- 10% |
| Frequency | 50-60Hz |
| Voltage | (0-80kV) AC / DC |
| Accuracy | +/- 1% kV |
| Application | Cable testing,Insulation Testing |
| Body Material | Mild Steel and PP Water Proof Box |
| connection type | IEC 60320 standard AC socket |
| Enclosure | Mild Steel And PP Water Proof Box |
| Duty cycle | 1 Min ON / 3 Min OFF ( we are also making as per customer requirement) |
Purpose of the testing:
To ensure that the electrical Equipments are capable of withstanding the over voltages that are met with in services Covers basic requirements procedures for testing on several Electrical apparatus. Normally, high voltage (HV) testing is to investigate the insulation performance.
Features:
M Power Electricals makes foolproof circuit design
Light weight and Easy to handle
Poly Propylene water proof box/Mild Steel Box
Ideal testing for Destructive , non-Destructive and maintenance applications
Testing Apparatus:
Transformer
Circuit breaker
Insulator
Cable…etc.
Specifications:
Brand:
M Power Electricals
Models:
(0-100kV)AC/ DC(Also we makes as per customer requirement)
Supply Voltage:
230V AC,50Hz,single phase +/- 5%
Leakage current:
As per customer requirement
Trip Settings:
Trip setting will be selected by using selector switch 10mA,25mA,50mA for AC and 5mA,15mA,25mA for DC (mA selection as per customer requirement)
kV selection:
kV selection will be selected by using selector switch (AC/DC)
kV meter range:
3 and ½ digit high Accuracy direct kV reading digital meter
Ammeter Range:
3 and ½ digit high accuracy direct mA reading digital meter
Additional Information:
Product Price :Get Latest Price
Product Details:| Voltage Range | 40 kV |
| Power Supply | 230V AC, 50Hz +-10% |
| Rated Output Current | 15/5mA, 25/15mA, 50mA/25mA (Customizable) |
| Resolution | 0.001 to 1 Count |
| Transformer Accuracy | +-1kV (Full Load) |
| Meter Accuracy | 0.5 / 1.0 Class |
| Rated Output Voltage | 30/40kV, 60kV/70kV, 70kV/80kV (Customizable) |
Product Price :Get Latest Price
Product Details:| Frequency | 50Hz +/-10% |
| Range | (0-70)kV AC (As Per Customer Requirement) |
| Test Time | 1 Min ON / 3 Min OFF ( we are also making as per customer requirement) |
| Humidity Resistant | Yes |
| Control | MCU Based Conrol Unit |
| Features | 1)foolproof circuit design 2)Light weight and Easy to handle |
| Indications | Zero interlock(yellow),HV on (Green),Overload trip (Red) |
| Output Current | 25mA DC (As Per Customer Requirement) |
| Accuracy | +/- 1kV |
| Body Material | Mild Steel and PP Water Proof Box |
| Input | 230V AC +/-10% |
Purpose of the testing:
To ensure that the electrical Equipments are capable of withstanding the over voltages that are met with in services Covers basic requirements procedures for testing on several Electrical apparatus. Normally, high voltage (HV) testing is to investigate the insulation performance.
Features:
M Power Electricals makes foolproof circuit design
Light weight and Easy to handle
Poly Propylene water proof box/Mild Steel Box
Ideal testing for Destructive , non-Destructive and maintenance applications
Testing Apparatus:
Transformer
Circuit breaker
Insulator
Cable…etc.
Specifications:
Brand:
M Power Electricals
Models:
(0-100kV) DC(Also we makes as per customer requirement)
Supply Voltage:
230V AC,50Hz,single phase +/- 5%
Leakage current:
As per customer requirement
Trip Settings:
Trip setting will be selected by using selector switch 10mA,25mA,50mA for AC and 5mA,15mA,25mA for DC (mA selection as per customer requirement)
kV selection:
kV selection will be selected by using selector switch (AC/DC)
kV meter range:
3 and ½ digit high Accuracy direct kV reading digital meter
Ammeter Range:
3 and ½ digit high accuracy direct mA reading digital meter
Additional Information:
Product Price :Get Latest Price
Product Details:| Channels | We are making single/3-3 phase but also customized to 6 channels |
| Model Name/Number | SI-30A |
| Output Voltage | 230 V AC |
| Surface Finish | Polished |
| Power | 230 volts +/- 10% |
| Usage/Application | Suitable for testing many different types of relay(current,voltage and power) |
| Frequency | 50Hz +/-10% |
| Accuracy | 0.5% |
| Metering | 4 and 1/2 digit independent high accuracy direct reading voltmeter and ammeter |
| Display | Digital |
| Connection Type | IEC |
| Weight | 21 kg Approx |
Description:
Secondary current injection tests are performed for the reason as which is to verify the correct functioning of a Realys and circuit breaker trip device during startup testing or maintenance inspections.
Solid-state trip units can be tested via secondary current injection using a test set specifically designed for the device to be tested. The main shortcoming of the secondary current injection test method is that only the solid-state trip unit logic and components are tested.
Brand:
· M Power Electricals
Input Voltage:
· 230V AC 50Hz {+/- 10%} Single Phase Supply
Output Voltage:
· AC 1 – (0-240V) AC at 2A
· AC 2 – (0-240 V) AC at 2A
· DC (0-310V) DC at 1.5A
Output Current:
· AC 1- (0-30A) AC (Current Position 1A,5A,10A,30A)
Frequency:
· 50Hz +/- 5%
Protections:
· Overload and Short Circuit
Metering:
· Independent Direct Reading Volt meter by using AC/DC selection
· High Accuracy Direct Ammeter
Digital Timer:
· MCU based 0 – 9999 milliseconds Auto range with NO/NC trip contact
Enclosure:
· Poly Propylene water proof box
Accuracy:
· +/- 0.5%
Usage:
· Universal Relay test kit
Packaging:
· box and Foam packaging
Additional Information:
Product Price :Get Latest Price
Product Details:| Usage/Application | Industrial |
| Brand | M Power |
| Voltage | 0-100kv AC / DC (We are also making as per customer requirement) |
| Accuracy | +/-1kV |
| Weight | 65kg Approx |
| Frequency | 50Hz +/- 5% |
| Dc Output Voltage Range | 0-100kV DC |
| Maximum Rated Current | 50mA AC / 25mA DC (We are also making as per customer requirement) |
| Output Voltage Accuracy | +/- 1kV |
| Output Voltage Waveform | AC-Sinusoidal / DC -Squarewave |
| Timer | 0-9999sec (As per customer requirement) |
Purpose of the testing:
To ensure that the electrical Equipments are capable of withstanding the over voltages that are met with in services Covers basic requirements procedures for testing on several Electrical apparatus. Normally, high voltage (HV) testing is to investigate the insulation performance.
Features:
M Power Electricals makes foolproof circuit design
Light weight and Easy to handle
Poly Propylene water proof box/Mild Steel Box
Ideal testing for Destructive , non-Destructive and maintenance applications
Testing Apparatus:
Transformer
Circuit breaker
Insulator
Cable…etc.
Specifications:
Brand:
M Power Electricals
Models:
(0-100kV) AC/DC(Also we makes as per customer requirement)
Supply Voltage:
230V AC,50Hz,single phase +/- 5%
Leakage current:
As per customer requirement
Trip Settings:
Trip setting will be selected by using selector switch 10mA,25mA,50mA for AC and 5mA,15mA,25mA for DC (mA selection as per customer requirement)
kV selection:
kV selection will be selected by using selector switch (AC/DC)
kV meter range:
3 and ½ digit high Accuracy direct kV reading digital meter
Ammeter Range:
3 and ½ digit high accuracy direct mA reading digital meter
Additional Information:
Product Price :Get Latest Price
Product Details:| Current Rating | 10A |
| Mains Input | 415V, 50Hz, AC 3-phase |
| Voltage Output | Phase-Neutral: 63V, 110V, 230V ACii) Phase-Phase: 110V, 220V, 415V AC |
| Output Metering | Measures 3-phase voltage, 3-phase current, kW, kWh, kVA, PF, and frequency |
| Meter Accuracy | Class 0.2, 0.5, or 1 (Customizable) |
| Protection | Fuse protection for all output voltage and current channels |
| Weight | 21 kg |
| Current Output | Variable 0-5A per phase, with optional outputs up to 100A AC |
Product Price :Get Latest Price
Product Details:| Protection | Short Circuit and Overload |
| Safety | Cooling System Provided |
| Display | Digital |
| Weight | 40 Kg Approx. |
| Range | 200A DC |
| Ammeter | 200A DC 0.2/0.5/1.0 Class |
| Capacity | 1500VA Max Output |
| Current Rating | 230A Maximum |
| Display Type | Digital |
| Driven Type | Continuous Injection |
| Material | Polypropylene Case (IP-65 Rating), Mild Steel Box |
| Measurement Range | 0-200A,0-2000Micro Ohm (As Per Customer Requirement) |
| Voltage | 7.5V DC |
The M Power Electricals make Contact Resistance Meter(Model - 200M) is a continuous injection based digital micro ohm meter. speaciallly designed to measure extremely low resistance of circuit breakers,contactors,isolaters,busbars,GIS and many other electrical components in Transmission/distribution Substation lines
Additional Information:
Product Price :Get Latest Price
Product Details:| Differential Relay Testing | Enables precise phase angle adjustments for accurate relay functionality testing. |
| Energy Meter Calibration | Assists in calibrating energy meters for accurate readings under varying loads |
| Power Flow Control | Adjusts active power flow to optimize system performance. |
| Load Balancing | Distributes load evenly across transmission lines, preventing overload. |
| Primary Voltage | 400V, 3-Phase |